Jump to content
I Forge Iron

dtesrgh

Members
  • Posts

    5
  • Joined

  • Last visited

Everything posted by dtesrgh

  1. Sorry for your confusion. Log splitter pumps are two stage pumps and I did clearly state that it’s a log splitter. Anyone who has built a hydraulic forging press would be aware of this. I was also quite polite I believe. I also stated that I believed the pump itself is the problem, but wanted hopefully get a second opinion by someone that has actually built their own, and therefore understands the components involved. im quite capable of using Google as well. I am going to replace the pump.
  2. Yep, thats why I'm here Complete log splitters are probably not rated by GPM, but all the pumps are. Thanks Frosty
  3. So I figured out your math error (I believe) and why they are rated the way they are. The two stage pump kicks into high gear at around 700 psi and the gpm at that rate is approx 3.5 gallons. If you look at the attached screenshot you'll see that 3.6gpm at 2500 requires only 6hp. So its not my motor and I'm open to suggestions
  4. Thanks for the quick replies, I appreciate it. I have not heard that general rule and I will have to look it up. I do know a similar sounding rule of 1gal of reservoir fluid for 1 gpm of pump.But that's completely different. I can tell you that your math works out to over three times the amount of power the pump manufacturer states is needed. (see attached pic). This pump (and most all 16gpm log splitter pumps I have looked at) require 8hp min of GAS engine which is equivalent to around 5hp of electric power if you use the 3/5 rule of thumb from electric to gas. In fact to confirm this I can also tell you my friend is running the same pump with 5hp electric with a 40ton cylinder and its a very capable press at 2500 psi. So if anything, I have more power than I need for this pump. Unless I am missing something? Not trying to argue and the information is appreciated. But I do know that these pumps are used all over in forging presses and do not have anything close to a 25 hp motor.
  5. Hello all, I am hoping you guys can help me troubleshoot my press. My pump is a 16gpm log splitter purchased from Surplus center. Unfortunately the tech I got hooked top with was zero help. (and I do mean zero) Below is a copy of one of my emails to them that describes my system. Im stumped and would like new eyes on it before I change out my pump. (and thats where im leaning to as the issues now) The pump will stall out and lock my motor under any load of around 2 seconds. Regardless where my pressure relief is set. A little about my system. Its all new. My motor is 7.5hp 3ph spinning at 3600rpm. All my lines are 1/2” and return to a 1” manifold with a filter rated at 50gpm. My pump sits directly in front of my 20 gal reservoir and is flooded. When running in idle the pressure gauge before my valve barely reads pressure so I know its flowing. I can slowly bump this pump up to 2500 and it wont stall and stayed pressed. But if I just let the pressure continuously build, it will quickly bog down and stall the motor. Even at pressures of only 1500. I have backed out the adjustment for the Hi side to the point where is wont stall but thats a max of 1300 psi. And increase of adjustment from here will start to stall the pump. Hope someone can help. Thanks!
×
×
  • Create New...